Fax:0511-86058085
E-mail :info@hltegang.com
NO.88 Yunhe Junmin East Road,
Lvcheng Town, Danyang City,
Jiangsu Province
Calculation formula of industrial electric wire length | ||
[ Release time:2011-8-23 Read:6669Times ] | ||
Calculation formula of industrial electric wire length To 45KW box-type electric furnace, for example, the use of three iron-chromium furnace wire, each furnace wire 15KW, the use of Star then Star-connected phase voltage of 220V, Use a diameter of 5.5mm electric furnace wire, calculated as follows: One of the requirements of the length of the wire: Phase power ÷ voltage = current Voltage ÷ current = resistance Resistance × 3.14 × square furnace radius ÷ 1.5 Above 1.5 for the electric resistance of wire, wire electric resistance of different different, you can ask the electric wire manufacturers. 15000 ÷ 220 = 68.181 220 ÷ 68.181 = 3.227 3.227 × 3.14 = 10.133 10.133 × (2.75 × 2.75 cross-sectional area) = 76.6 76.6 ÷ 1.5 = 51.0 m (1.5 is the electric resistance of the electric wire) The length of each electric furnace wire is 51 meters Surface load calculation W / c ㎡ The low temperature furnace is 1.2-1.5; the medium temperature furnace is 1.6-1.9; the high temperature furnace is 1.8-2.3 3.14 × 0.55 × 5100 cm = 8807.7 15000 ÷ 88.077 = 1.7 The surface load of this electric furnace is: 1.7 |
||